A new dose-volume-based Plan Quality Index for IMRT plan comparison
Lucullus Hing Tong Leung1, Monica Wai Kwan Kan, Ashley Chi Kin Cheng
1Department of Oncology, Princess Margaret Hospital, Hong Kong SAR, China. leunght@ha.org.hk
Background And Purposes:
To develop a dose-volume-based Plan Quality Index for IMRT plans.
Materials And Methods:
This study used a H(ealthy) Tissue Conformity Index to describe the overall plan conformity, a M(erit) function to describe the target coverage and a P(enalty) function to evaluate doses to critical organs. The Euclidean distance (PQI) between (H, M, P) and (1,1,1) represented the quality of a treatment plan. By checking the polarity of each term in M and P, one might conclude if the plan was satisfied with the given treatment protocol. Ten prostate plans (3-DCRT and IMRT) and 20 NPC IMRT plans were used to test PQI, Conformation Number (CN), COnformal INdex (COIN). EUD was used as a vehicle to explain the results. This study defined the power of a quality index as the ratio of the absolute difference to the mean of the same index of two plans, to compare the discerning power of PQI, CN and COIN.
Results:
The plan quality discerning power of PQI, COIN and CN was 20.6%, 8.2% and 5.5%, respectively, in prostate plans.
Conclusion:
PQI improved the plan quality discerning power and was capable of discerning qualified and unqualified treatment plans.