Determination of fluoroquinolone antibiotics in surface waters from Mondego River by high performance liquid
Angelina Pena1, Daniela Chmielova, Celeste M Lino
1Group of Bromatology, Center of Pharmaceutical Studies, University of Coimbra, Portugal. apena@ci.uc.pt
Abstract:
A novel LC-fluorescence detection method based on the use of a monolithic column for the determination of norfloxacin, ciprofloxacin, and enrofloxacin antibiotic residues in environmental waters was developed. Fluoroquinolones (FQs) were isocratically eluted using a mobile phase consisting of 0.025 M phosphoric acid solution at pH 3.0 with tetrabutylammonium and methanol (960:40, v/v) through a Chromolith Performance RP-18e column (100x4.6 mm) at a flow rate of 2.5 mL/min and detected at excitation and emission wavelengths of 278 and 450 nm, respectively. After acidification and addition of EDTA, water samples were extracted using an Oasis HLB cartridge. Linearity was evaluated in the range of 0.05 to 1 microg/mL and correlation coefficients of 0.9945 for norfloxacin, 0.9974 for ciprofloxacin, and 0.9982 for enrofloxacin were found. The limit of quantification was 25 ng/L for the three FQs. The recovery of FQs spiked into river water samples at 25, 50, and 100 ng/L fortification levels ranged from 76.5 to 91.0% for norfloxacin, 78.5 to 97.2% for ciprofloxacin, and 79.4 to 93.6% for enrofloxacin. This method was successfully applied to the analysis of water samples from the Mondego River, and ciprofloxacin and enrofloxacin residues were detected in eight water samples.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Instrumentation
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...