Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Measurement of pulse wave velocity using pulse wave Doppler ultrasound: comparison with arterial tonometry
Benyu Jiang1, Baoming Liu, Karen L McNeill
1King's College of London, Cardiovascular Division, Thomas's Hospital, London, UK. ben_yu.jiang@kcl.ac.uk
Abstract:
Pulse wave velocity (PWV), the speed of propagation of arterial pressure waves through the arterial tree, is related to arterial stiffness and is an important prognostic marker for cardiovascular events. In clinical practice PWV is commonly determined by arterial tonometry, with a noninvasive pressure sensor applied sequentially over carotid and femoral arteries. The electrocardiogram (ECG) is used as a timing reference to determine the time delay or "transit time" between the upstroke of carotid and femoral pulse waveforms. Commercially available vascular ultrasound scanners provide a pulsed wave (PW) Doppler velocity signal, which should allow determination of carotid-femoral transit time and hence PWV. We compared carotid-femoral PWV measured by tonometry and by PW Doppler ultrasound (Seimens, Apsen scanner with 7 MHz linear transducer) in asymptomatic subjects (n = 62, 26 male, aged 21 to 72 y). To test for intra-subject and inter-observer variation, ten subjects were scanned by one observer on two occasions 2 wk apart and by two observers on same day. PWV by tonometry ranged from 5.3 to 15.0 m/s. There was no significant difference between mean values of PWV obtained by the two techniques (mean difference: 0.3 m/s, standard deviation of difference: 1.5 m/s), which were closely correlated (r = 0.83). The coefficient of variation for repeated measures on the same subject by the same observer was 10.1% and the inter-observer coefficient of variation was 5.8%. These results suggest a commercial ultrasound scanner can be used to measure PWV, giving results that are reproducible and closely correlated with those obtained by arterial tonometry. (E-mail: ben_yu.jiang@kcl.ac.uk).
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement