Uncooled infrared imaging device based on optimized optomechanical micro-cantilever array
Related Experiment Video
Updated: Jul 9, 2026

Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
Fengliang Dong1, Qingchuan Zhang, Dapeng Chen
1CAS Key Laboratory of Mechanical Behavior and Design of Materials, University of Science and Technology of China, Hefei, Anhui 230027, China.
Abstract:
It is a major issue to improve the thermo-mechanical sensitivity of uncooled optomechanical focal plane arrays (FPAs) for infrared imaging. This work presents an optimized multi-fold interval metallized leg (IML) configuration to increase the thermo-mechanical sensitivity of an uncooled optomechanical bi-material micro-cantilever array. The inclination angle changes of the cantilever elements are measured in the IR imaging system using an optical readout with a knife-edge filtering operation in the spectrum plane. The multi-fold IML configuration consists of alternately connected unmetallized and metallized legs. With the optimized fold number, the thermo-mechanical sensitivity of a micro-cantilever array can be amplified to two times of one-fold IML for a 120 microm x 120 microm element with 1 microm thick SiNx/0.2 microm thick Au films. Room temperature objects are imaged with the fabricated FPA containing 160 x 160 elements and a 12-bit CCD. Further modeling analysis shows that the experimental results are well accordant with the theoretical calculation. An important practical feature of the implemented approach is its straightforward fabrication for a large FPA, without growing complexity and cost.