Related Experiment Video
Updated: Jul 9, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
An investigation of statistical power for continuous arterial spin labeling imaging at 1.5 T
Iris Asllani1, Ajna Borogovac, Clinton Wright
1The Department of Radiology, Columbia University College of Physicians and Surgeons, 630 West 168th Street, Columbia University, New York, New York 10032, USA. ia2026@columbia.edu
Abstract:
Variance estimates can be used in conjunction with scientifically meaningful effect sizes to design experiments with type II error control. Here we present estimates of intra- and inter-subject variances for region of interest (ROI) from resting cerebral blood flow (CBF) maps obtained using whole brain, spin echo echoplanar (SE-EPI) continuous arterial spin labeling (CASL) imaging on 52 elderly subjects (age=70.5+/-7.9 years, 29 males). There was substantial intrasubject systematic variability in CBF of gray matter ROIs corresponding to a range of standard deviations=[39-168] (ml/(100 g min)). This variability was mainly due to two factors: (1) an expected inverse relationship between ROI volume and intrasubject variance and (2) an increased effective post-labeling delay for more superior slices acquired later in the sequence. For example, intrasubject variance in Brodmann area 4 (BA 4) was approximately 8 times larger than in hippocampus, despite their similar gray matter volumes. Estimated ROI-wise power was computed for various numbers of acquired CBF images, numbers of subjects, and CBF effect sizes for two experimental designs: independent sample t-test and paired t-test. The theoretical effects of pulse sequence and field strength on general applicability of these results are discussed.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Magnetic Resonance Imaging