A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Complications of silicone stent insertion in patients with expiratory central airway collapse
Septimiu D Murgu1, Henri G Colt
1Department of Medicine, Pulmonary and Critical Care Medicine, University of California School of Medicine, Irvine, California, USA. smurgu@uci.edu
Background:
Silicone stent insertion is an alternative treatment for expiratory central airway collapse. This study evaluates the complications (mucus plugging, migration, and granulation tissue) associated with stenting in patients who failed medical therapy and were not surgical candidates.
Methods:
Chart review from 15 consecutive patients treated by silicone stent insertion was done over a 2-year period. Outcomes included (1) changes in functional class, extent and severity of airway collapse (graded from 1 to 4 by using a multidimensional system), procedure- and stent-related complications at 48 hours after stent insertion; (2) frequency of stent-related complications; and (3) frequency of emergent flexible and rigid bronchoscopy (scheduled or emergent) over the follow-up period.
Results:
Mean functional class and severity and extent of airway collapse significantly improved within 48 hours after treatment (p < 0.05). There were no perioperative deaths. Stent-related complications within 48 hours after stent insertion occurred in 3 patients (1 granulation, 1 migration, and 1 mucus plugging). The mean duration of follow-up for the 12 patients who underwent clinical and bronchoscopic follow-up was 188 days. Twenty-six stent-related complications (12 mucus plugs, 8 migrations, and 6 granulation tissues) were seen in 10 of the 12 patients. Five emergent flexible bronchoscopies and 14 rigid bronchoscopies (6 of which were emergent) were performed during the follow-up period.
Conclusions:
Silicone stent insertion improves functional status immediately after intervention in patients with expiratory central airway collapse, but is associated with a high rate of stent-related complications and need for repeat bronchoscopic interventions.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...