Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Hooke's Law01:26

Hooke's Law

Hooke's law, a pivotal principle in material science, establishes that the strain a material undergoes is directly proportional to the applied stress, defined by a factor called the modulus of elasticity or Young's modulus.
Generalized Hooke's Law01:22

Generalized Hooke's Law

The generalized Hooke's Law is a broadened version of Hooke's Law, which extends to all types of stress and in every direction. Consider an isotropic material shaped into a cube subjected to multiaxial loading. In this scenario, normal stresses are exerted along the three coordinate axes. As a result of these stresses, the cubic shape deforms into a rectangular parallelepiped. Despite this deformation, the new shape maintains equal sides, and there is a normal strain in the direction of the...
Bending of Members Made of Several Materials01:11

Bending of Members Made of Several Materials

In analyzing a structural member composed of two different materials with identical cross-sectional areas, it is crucial to understand how their distinct elastic properties affect the member's response under load. The analysis involves assessing stress and strain distributions using the transformed section concept, which accounts for variations in material properties.
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Stability of structures01:14

Stability of structures

In mechanical engineering, the stability of systems under various forces is critical for designing durable and efficient structures. One fundamental way to explore these concepts is by analyzing systems like two rods connected at a pivot point, O, with a torsional spring of spring constant k at the pivot point. This system is similar in appearance to a scissor jack used to change tires on a car. In this case, the arms of the linkage (equivalent to the rods in this system) are entirely vertical,...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity01:15

Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity

Deformation occurs in axial and transverse directions when an axial load is applied to a slender bar. This deformation impacts the cubic element within the bar, transforming it into either a rectangular parallelepiped or a rhombus, contingent on its orientation. This transformation process induces shearing strain. Axial loading elicits both shearing and normal strains. Applying an axial load instigates equal normal and shearing stresses on elements oriented at a 45° angle to the load axis.
General Case of Eccentric Axial Loading01:12

General Case of Eccentric Axial Loading

Unsymmetrical bending occurs when the bending moment applied to a structural member does not align with its principal axis. This misalignment leads to complex stress distributions and deflection patterns that differ from symmetrical bending, which are essential for designing structures to withstand different loading conditions.
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Infrared spectroscopy of serum as a potential diagnostic screening approach for naturally occurring canine osteoarthritis associated with cranial cruciate ligament rupture.

Osteoarthritis and cartilage·2019
Same author

Olfactory responses of Amblyomma maculatum to rumen fluid and other odourants that attract blood-seeking arthropods.

Medical and veterinary entomology·2019
Same author

Bermudagrass Resistance to Spring Dead Spot Caused by Ophiosphaerella herpotricha.

Plant disease·2019
Same author

Effect of a Select Group of Seed Protectant Fungicides on Growth of Sclerotinia minor In Vitro and Its Recovery from Infested Peanut Seed.

Plant disease·2019
Same author

The Effects of Temperature and Wetness Period on the Development of Spinach White Rust.

Plant disease·2019
Same author

Development of a Weather-Based Advisory Program for Scheduling Fungicide Applications for Control of White Rust of Spinach.

Plant disease·2019

Related Experiment Video

Updated: Jul 9, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
10:09

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models

Published on: October 9, 2014

Stiffness of modified Type 1a linear external skeletal fixators.

H F Reaugh1, M C Rochat, C W Bruce

  • 1Dallas Veterinary Surgical Center, Dallas, Texas, USA. hreaugh@sbcglobal.net

Veterinary and Comparative Orthopaedics and Traumatology : V.C.O.T
|November 27, 2007
PubMed
Summary

Modified external skeletal fixator (ESF) frames showed increased stiffness. Type 1a-MOD and 1a-OUTSIDE designs significantly improved stiffness in axial compression and cranial-caudal bending compared to standard Type 1a frames.

More Related Videos

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
05:34

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats

Published on: May 20, 2019

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
08:20

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator

Published on: March 24, 2019

Related Experiment Videos

Last Updated: Jul 9, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
10:09

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models

Published on: October 9, 2014

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
05:34

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats

Published on: May 20, 2019

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
08:20

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator

Published on: March 24, 2019

Area of Science:

  • Orthopedic biomechanics
  • Biomaterials engineering
  • Surgical device innovation

Background:

  • External skeletal fixators (ESFs) are crucial in orthopedic trauma management.
  • Type 1a ESF frames offer a basic unilateral construct.
  • Enhancing ESF frame stiffness is vital for improved fracture healing and stability.

Purpose of the Study:

  • To evaluate the biomechanical stiffness of modified Type 1a external skeletal fixator (ESF) frames.
  • To assess stiffness under axial compression (AC), cranial-caudal bending (CCB), and medial-lateral bending (MLB).
  • To determine if modifications increase unilateral frame stiffness without proportional complexity.

Main Methods:

  • Construction of nine, eight-pin frames for each design: Type 1a, Type 1a-MOD (modified pin placement), Type 1a-INSIDE, and Type 1a-OUTSIDE (additional rods).
  • Utilized IMEX SK clamps, 3.2 mm pins, and 9.5 mm carbon fibre rods with Delrin bone models.
  • Subjected constructs to repetitive, non-destructive loading (AC, CCB, MLB) using a materials testing machine.

Main Results:

  • Type 1a-MOD and Type 1a-OUTSIDE constructs demonstrated significantly greater stiffness in CCB and AC compared to the standard Type 1a frame.
  • All modified constructs (1a-MOD, 1a-INSIDE, 1a-OUTSIDE) exhibited significantly higher stiffness in MLB than the Type 1a frame.
  • Stiffness was quantified in N/mm derived from load-deformation curve analysis.

Conclusions:

  • Modifications to the Type 1a ESF frame can significantly enhance construct stiffness.
  • The 1a-MOD and 1a-OUTSIDE designs offer improved biomechanical performance, particularly in bending and compression.
  • These enhanced ESF designs hold potential for more stable fracture fixation without substantial increases in complexity.