Small-phase solution to the phase-retrieval problem
Related Experiment Video
Updated: Jul 9, 2026

08:39
Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
Published on: January 28, 2019
Optics Letters
|November 28, 2007
Abstract:
A solution to the phase-retrieval problem when the unknown phase is small is presented. The solution specifies the even and odd parts of the unknown phase in two separate equations. The odd part requires a single intensity measurement, and the even part requires two measurements. Phase diversity is used for the second measurement, and computer simulations are given.
Related Concept Videos
The Phase Rule
The phase rule describes the relationship between the variance (degrees of freedom), the number of components, and the number of phases in a system at equilibrium.Variance is a concept that denotes the number of independent intensive properties (properties are those that do not depend on the amount of material in the system), such as temperature, pressure, and composition, that can be altered without impacting the number of phases in equilibrium.In a single-component system, such as pure water,...
Time and frequency -Domain Interpretation of Phase-lead Control
Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Phasor Arithmetics
Phasors and their corresponding sinusoids are interrelated, offering unique insights into the behavior of alternating current (AC) circuits. One way to understand this relationship is through the operations of differentiation and integration in both the time and phasor domains.
When the derivative of a sinusoid is taken in the time domain, it transforms into its corresponding phasor multiplied by j-omega (jω) in the phasor domain, where j is the imaginary unit, and ω is the angular frequency.
When the derivative of a sinusoid is taken in the time domain, it transforms into its corresponding phasor multiplied by j-omega (jω) in the phasor domain, where j is the imaginary unit, and ω is the angular frequency.
Phase-lead and Phase-lag Controllers
Understanding the working function of different types of controllers can be illustrated with practical analogies, such as adjusting a stereo's volume equalizer. Cranking up the bass involves a phase-lead controller, which functions as a high-pass filter, while increasing the treble uses a phase-lag controller, which acts as a low-pass filter. PD controllers, similar to high-pass filters, enhance the system's response to high-frequency components. PI controllers, akin to low-pass filters, manage...
Reconstruction of Signal using Interpolation
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
The Y-to-Y Circuit
In a balanced four-wire wye-to-wye system, the arrangement involves wye-connected sinusoidal voltage sources and loads, connected through a neutral wire that links the neutral nodes of the source and load. The load impedance is connected across each phase of the load. The wye-connected source can be connected to the wye-connected load in four-wire and three-wire arrangements. A three-phase system is considered balanced when the load on each phase is equal, leading to uniform current flow and...