Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Published on: May 2, 2018
Laboratory and field testing of sampling methods for inhalable and respirable dust
Markku Linnainmaa1, Juha Laitinen, Ari Leskinen
1Finnish Institute of Occupational Health, Kuopio, Finland. markku.linnainmaa@ttl.fi
Abstract:
The performance of four sampling devices for inhalable dust and three devices for respirable dust was tested with different kinds of dusts in the laboratory and in the field. The IOM sampler was chosen as the reference method for inhalable dust, and the IOM sampler provided with the porous plastic foam media was used as the reference method for respirable dust. The other tested instruments were the Button sampler, the optical Grimm aerosol monitor, and the Dekati two-stage cascade impactor with cutoff sizes of 10 and 4 mu m. The study confirmed the applicability of the IOM and Button samplers. The new foam product followed the respirable criteria well. However, the foam sampler was unstable for measuring inhalable dust, probably due to its moisture absorption. In addition, high dust loads should be avoided with the foam sampler due to increase in filtering efficiency. The concentrations of inhalable dust measured with the Button sampler, the Grimm monitor, and the impactor sampler were usually close to those measured with the reference sampler. On the other hand, impactor sampling yielded higher respirable dust concentrations than the reference method in the field, which may have been caused by particle bounce; high dust loads should be avoided while using the impactor. The results also showed that the Grimm monitor enables real-time dust concentration determinations that are accurate enough for routine monitoring of occupational exposure and for testing efficiency of control measures in workplaces.
More Related Videos
10:10Assessment of the Acute Inhalation Toxicity of Airborne Particles by Exposing Cultivated Human Lung Cells at the Air-Liquid Interface
Published on: February 23, 2020
05:07Development of a Nose-only Inhalation Toxicity Test Chamber That Provides Four Exposure Concentrations of Nano-sized Particles
Published on: March 18, 2019
Related Concept Videos
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...