Related Experiment Video
Updated: Jul 9, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Pulsatile versus nonpulsatile flow to maintain the equivalent coronary blood flow in the fibrillating heart
Jae Seung Jung1, Ho Sung Son, Choon Hak Lim
1Thoracic and Cardiovascular Surgery, Korea Artificial Organ Center, Korea University, Seoul, Korea.
Abstract:
How much flow is required by a nonpulsatile pump to match the coronary blood flow equivalent to that of pulsatile pump? A cardiopulmonary bypass circuit from the right atrium to the ascending aorta was constructed in a ventricular fibrillation model using 13 Yorkshire swine. The animals were randomly divided into two groups: CONTROL (pulsatile T-PLS, n = 7) or EXPERIMENTAL (nonpulsatile Biopump, n = 6). The hemodynamic data at mid-LAD level was measured with a flow meter at baseline and every 20 minutes after pump flow initiation. The pump flow was started from 2 L/min in both groups (67 +/- 8 in CONTROL and 70 +/- 9 ml/kg/min in EXPERIMENTAL; p = NS), and the pump flow of the EXPERIMENTAL group was increased to match the coronary flow of the CONTROL group. To maintain mean velocity and flow in the LAD, the EXPERIMENTAL group required significantly higher pump flow at 20, 40, and 60 minutes (84 +/- 17 vs. 67 +/- 8, 87 +/- 24 vs. 67 +/- 8, 85 +/- 18 vs. 67 +/- 8 ml/kg/min, respectively, p < 0.05). The LAD diameter was substantially smaller in the CONTROL group and the resistance index was significantly lower in the CONTROL group at 80 minutes and 120 minutes after bypass (0.56 +/- 0.26 vs. 0.87 +/- 0.20 and 0.61 +/- 0.23 vs. 0.90 +/- 0.06; p < 0.05). In conclusion, we found that the nonpulsatile pump may require 25%-28% higher pump flow than the pulsatile pump to maintain equivalent coronary blood flow.
Related Concept Videos
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Physiology of the Heart: The Cardiac Cycle
Diastole: The Relaxation Phase
During diastole, all four heart chambers relax. The atrioventricular (AV) valves open, and the semilunar valves close. This phase sees the lowest chamber pressures, promoting ventricular filling. Venous blood enters the heart through the...
Blood Flow
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Pulse
The pulse serves as a clinical indicator...
Cardiac Cycle
During the cardiac cycle, blood flow through the heart is regulated entirely by changing pressure gradients. This sequence of events begins with the heart in a state of total relaxation, known as mid-to-late diastole, during which blood passively flows from...