Related Experiment Video
Updated: Jul 9, 2026

RNAscope for In situ Detection of Transcriptionally Active Human Papillomavirus in Head and Neck Squamous Cell Carcinoma
Published on: March 11, 2014
[Clinical evaluation of the xMAP technology in detection of high-risk human papillomavirus]
Guang-dong Liao1, Xiao-yan Zhang, Yu-hua Gao
1Department of Cancer Epidemiology, Cancer Institute, CAMS and PUMC, Beijing 100021, China.
Objective:
To evaluate the clinical application value of flexible multi-analyte profiling (xMAP) technology in detecting high-risk human papillomavirus (HR-HPV).
Methods:
Totally 1 061 women, aged 21-65 years, were randomly enrolled into the study. Cervical exfoliated cells were used in xMAP technology and hybrid capture II (hc2). Pathological diagnosis was used as golden standard. Consistency of these two methods was assessed.
Results:
The sensitivity and specificity of xMAP technology were 80.31% and 85.83%, respectively. The positive and negative predictive values were 44.5% and 96.9%, respectively. The Kappa value for consistency between xMAP technology and hc2 was 0.58.
Conclusions:
The specificity of xMAP technology is similar to hc2 test, but the sensitivity is inferior to hc2. However, these two methods show good consistency in the detection of HR-HPV.