Development and characterization of a standardized ELISA including a reference serum on each plate to detect
Kazutoyo Miura1, Andrew C Orcutt, Olga V Muratova
1Malaria Vaccine Development Branch, National Institute of Allergy and Infectious Diseases, National Institutes of Health, Rockville, MD 20852, USA. kmiura@niaid.nih.gov <kmiura@niaid.nih.gov>
Abstract:
Enzyme linked immunosorbent assay (ELISA) has been widely used to measure antibody titers for evaluating the immunogenicity of a vaccine. However, there is as yet no generally accepted way of expressing the ELISA results in the case of experimental vaccines, since there is usually no uniform standard. Both end point and single dilution methods have significant disadvantages. In this paper, we obtained reproducible data with fewer dilutions of samples by addition of serially diluted standard serum to each ELISA plate. Since this ELISA method gives reliable antibody titer with less labor than other methods, it can strongly support vaccine development.
Related Concept Videos
Malaria
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.