Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Phase-retrieval method for measuring small contact angles of pentane on water.

Applied optics·2019
Same author

Environmental scanning electron microscopy of the surface of normal and vitrified leaves of Gypsophila paniculata (Babies Breath) cultured in vitro.

Plant cell reports·2013
Same author

Optical imaging of inhomogeneous magnetic fields through the deformation of paramagnetic liquid films.

Applied optics·2010
Same author

Interference microscopy and Fourier fringe analysis applied to measuring the spatial refractive-index distribution.

Applied optics·2010
Same author

Measurement of the integrated water vapor content in the atmosphere by a radiometric method.

Applied optics·2010
Same author

Atmospheric aerosols investigated by inversion of experimental transmittance data.

Applied optics·2010

Related Experiment Video

Updated: Jul 9, 2026

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

Superresolution in far-field imaging.

I Leiserson, S G Lipson, V Sarafis

    Optics Letters
    |December 7, 2007
    PubMed
    Summary
    This summary is machine-generated.

    Superresolved imaging was achieved using interferometric image multiplication, inspired by complex filters. This method surpassed the Sparrow limit, achieving 55% resolution for incoherent objects.

    More Related Videos

    Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging
    10:01

    Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging

    Published on: September 8, 2017

    Super-Resolution Imaging and Shared Management: A Protocol for Confocal Microscopy with Multiplex Detection
    07:42

    Super-Resolution Imaging and Shared Management: A Protocol for Confocal Microscopy with Multiplex Detection

    Published on: February 24, 2026

    Related Experiment Videos

    Last Updated: Jul 9, 2026

    Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
    06:25

    Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

    Published on: February 12, 2014

    Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging
    10:01

    Demonstration of a Hyperlens-integrated Microscope and Super-resolution Imaging

    Published on: September 8, 2017

    Super-Resolution Imaging and Shared Management: A Protocol for Confocal Microscopy with Multiplex Detection
    07:42

    Super-Resolution Imaging and Shared Management: A Protocol for Confocal Microscopy with Multiplex Detection

    Published on: February 24, 2026

    Area of Science:

    • Optics and Photonics
    • Image Processing

    Background:

    • Complex filters were proposed by Toraldo di Francia in 1952.
    • Superresolution imaging aims to overcome the diffraction limit.

    Purpose of the Study:

    • To achieve superresolved imaging using interferometric image multiplication.
    • To validate the application of complex filter concepts for enhanced resolution.

    Main Methods:

    • Interferometric image multiplication technique.
    • Application of complex filters inspired by Toraldo di Francia's work.

    Main Results:

    • Superresolved imaging was successfully demonstrated.
    • A resolution limit of 55% of the Sparrow limit was achieved for incoherent objects.

    Conclusions:

    • Interferometric image multiplication is an effective method for superresolution.
    • The study validates the practical application of complex filter theory in advanced imaging.