Related Experiment Video
Updated: Jul 9, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Disinfection of Acinetobacter baumannii-contaminated surfaces relevant to medical treatment facilities with
Vipin K Rastogi1, Lalena Wallace, Lisa S Smith
1BioDefense Team, Research and Technology Directorate, U.S. Army-Edgewood Chemical and Biological Center, Aberdeen Proving Grounds, MD 21010, USA.
Abstract:
The efficacy of ultraviolet C (UVC) light (100-280 nm) in the decontamination of three hospital-related surfaces, namely, unpainted/painted aluminum (bed railings), stainless steel (operating tables), and scrubs (laboratory coats), was investigated. Acinetobacter baumannii cells were inoculated (10(5) or 10(3) cells) on small coupons and dried overnight in a class II biosafety cabinet. Drying resulted in < or =50% loss of viability. The UVC fluence of 90 J/m2 was observed to be very effective in the decontamination of cells from all metal coupon surfaces (complete killing). However, the same fluence was ineffective in the decontamination of scrubs. The effectiveness of two other common disinfection practices, that is, 15 minutes of boiling or spraying with 70% ethanol, was investigated for the scrubs. Although ethanol treatment was ineffective, the boiling treatment was very effective (complete killing). These results establish that metal surfaces can be decontaminated with UVC irradiation and boiling treatment is effective for scrub decontamination.
More Related Videos
09:29In Vivo Investigation of Antimicrobial Blue Light Therapy for Multidrug-resistant Acinetobacter baumannii Burn Infections Using Bioluminescence Imaging
Published on: April 28, 2017
08:56Investigation of a Blue Light LED Device to Suppress Wound Pathogens Using a Collagen-Based Synthetic Skin Model
Published on: February 24, 2026
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Chemical Agents for Microbial Control
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...