On-line gas-free electrodialytic eluent generator for capillary ion chromatography
Bingcheng Yang1, Masaki Takeuchi, Purnendu K Dasgupta
1Department of Chemistry and Biochemistry, The University of Texas at Arlington, Arlington, Texas 76019-0065, USA.
Abstract:
Both low- and high-pressure, gas-free, capillary-scale electrodialytic generators for eluents in ion chromatography are described. While the low-pressure devices rely on planar or tubular membranes, the high-pressure devices rely on ion-exchange beads used both as one-way ionic gates and as ball-on-seat valves to provide sealing. The high-pressure device is easily implemented in the form of a commercial cross fitting and can withstand at least 1400 psi. By design these devices do not produce gas in the eluent channel; hence, it is not necessary to remove gas afterward. With appropriate electrolytes and electrode polarities, such devices can produce either acid or base or salt. In regard to ionic transport, the behavior of these devices fully corresponds to that of a semiconductor diode. To our knowledge, this is the first time such complete equivalence of ion transport through ion-exchange media and with the more familiar example of electron transport through a semiconductor diode under both forward- and reverse-biased conditions have been demonstrated. Reverse bias can be applied to minimize/prevent Donnan-forbidden leakage or ion exchange. Even with 4 M KOH in the electrode compartments and 4 microL/min water flowing through the eluent channel, with a reverse bias of -12 V, the leakage KOH concentration is <30 microM, whereas the KOH concentration with zero voltage applied, herein after termed open circuit penetration (OCP), is 1600 microM. It is suggested that this OCP occurs not as much through Donnan-forbidden leakage but via ion exchange. Chromatograms and reproducibility data are presented for both isocratic and gradient chromatography, using ion-exchange, latex-modified, open tubular and packed monolithic columns.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...