Related Experiment Video
Updated: Jul 9, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Comparison between dynamic headspace and headspace solid-phase microextraction for gas chromatography of BTEX in
Irena Brcić Karaconji1, Ljiljana Skender
1Institute for Medical Research and Occupational Health, Zagreb, Croatia. ibrcic@imi.hr
Abstract:
The aim of this study was to compare two extraction procedures: dynamic headspace-purge and trap (PT) and headspace solid-phase microextraction (HS-SPME) for gas chromatographic determination of benzene, toluene, ethylbenzene, and isomeric xylenes (BTEX) in urine with photoionization (PID) and mass spectrometric (MS) detection, respectively. Both methods showed linearity in the range of interest [(50-2000) ng L-1], good accuracy (80% to 100%), and repeatability (RSD< or =11%). Detection limits were in the low ng L-1 level for both methods, although slightly greater sensitivity was found for the PT method. In comparison with PT, HS-SPME was simpler and required less time for analysis. Although the analytical features of both examined methods are appropriate for biomonitoring of environmental exposure to BTEX, only the HS-SPME-GC-MS method is recommended for routine analysis of BTEX in urine. The method was applied for the quantitative analysis of BTEX in urine samples collected from non-smokers (n=10) and smokers (n=10).
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
04:19An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Elution Process