Related Experiment Video
Updated: Jul 9, 2026

Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Approximal caries diagnosis after data import from different digital radiography systems: interobserver agreement and
A G Schulte1, A Wittchen, V Stachniss
1Department of Conservative Dentistry, Rupprechts-Karls Universitat, Heidelberg, Germany.
Aims:
To evaluate the agreement of approximal caries diagnosis obtained with different types of digital radiography systems after image import into a reference system.
Methods:
Digital radiographs were taken from 30 extracted human premolars with 60 diagnostic surfaces using a reference and two test systems from which images were imported as TIFF files. Four observers evaluated the radiographs using the reference software. Teeth were sectioned for histology. Agreement between histology and each technique was calculated using receiver operating characteristic (ROC) statistics.
Results:
The areas under the ROC curves were not significantly different between reference and test systems.
Conclusions:
Importing files from different programs did not affect diagnostic accuracy.