Related Experiment Video
Updated: Jul 9, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Male and female upper body sweat distribution during running measured with technical absorbents
George Havenith1, Alison Fogarty, Rebecca Bartlett
1Department of Human Sciences, Loughborough University, Loughborough, LE11 3TU, UK. G.Havenith@lboro.ac.uk
Abstract:
Body sweat distribution over the upper body in nine clothed male and female runners of equal fitness while running at 65% VO(2max) and subsequent 15-min rest in a moderate climate (25 degrees C, 53% rh) was investigated using technical absorbent materials to collect the sweat produced. No significant difference in whole body mass loss (male 474 SD 80; female 420 SD 114 g m(-2) h(-1)) nor surface weighted average of all tested zones for exercise (male 636 SD 165; female 565 SD 222 g m(-2) h(-1)) nor rest (male 159 SD 46; female 212 SD 75 g m(-2) h(-1)) were observed. Local sweat rate (LSR) ranges were large and overlapped substantially in most areas. Males showed higher LSR for the mid-front (P < 0.05), sides (P < 0.05), and mid lateral back (P < 0.01) compare to females. Both sexes showed similar sweat distribution patterns over the upper body with some exceptions. Males showed higher relative (local to overall) sweat rates than females for the mid lateral back (P < 0.001), while it was lower for the upper arm (P < 0.001), lateral lower back (P < 0.05), and upper central back (P < 0.05). Sweating in both sexes was highest along the spine, and higher on the back as a whole than the chest as a whole. Upper arm sweat rate was lowest. Males showed a higher ratio of highest to lowest LSR (4.4 vs. 2.8; P < 0.05). The present study has provided more detailed information, based on more subjects, on upper body sweat distribution than previously available, which can be used in clothing design, thermo-physiological modelling, and thermal manikin design.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Accessory Structures of the Skin: Sweat Glands
Sweat glands are classified as merocrine glands; that is, the secretions are excreted by exocytosis through a duct without affecting the cells of the gland. There...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Mechanisms of Heat Transfer
Conduction, accounting for approximately 3% of body heat loss at rest, is the process of exchanging heat between molecules of two materials in direct contact. This can result in both heat loss and gain. For instance, when the body is submerged in water, which conducts heat 20 times more effectively than air, it can either lose or gain significant heat.
