Related Experiment Video
Updated: Jul 9, 2026

Manual Muscle Testing: A Method of Measuring Extremity Muscle Strength Applied to Critically Ill Patients
Published on: April 12, 2011
Cervical muscle strength measurement is dependent on the location of thoracic support
A Rezasoltani1, J Ylinen, A-H Bakhtiary
1University of Shahid Beheshti (Medical Sciences), Faculty of Rehabilitation, Department of Physiotherapy, Damavand Avenue, 16169 Tehran, Iran. arezasoltani@yahoo.com
Background:
In all studies in which the strength of the neck extensor muscles has been measured, the level of thoracic support has been adjusted differently so direct comparison of the results is not possible.
Objective:
To measure and compare the isometric force and isometric torque of neck extensor muscles at different levels of thoracic support.
Methods:
Twenty healthy women volunteered for the study. The maximum isometric force of the neck extensor muscles was measured with the thoracic support located at five different levels. The highest level was set at the level of the spine of the scapula (level I) and the other levels were located 2.5 cm lower than the previous one, with the lowest level set 10 cm below the highest level. The maximum isometric torque for each level was calculated by multiplying the isometric force by the length of the lever arm measured from the upper tip of the thoracic support to the centre point of the cell load at the occiput.
Results:
The maximum isometric force and maximum isometric torque of the neck extensor muscles were increased step by step from 130.5 N to 138.9 N, 141.9 N, 147.9 N and 155.4 N and from 33.7 Nm to 38.7 Nm, 42.5 Nm, 47.2 Nm and 52.7 Nm, respectively. Except for the isometric force of the cervical extensor muscles measured at levels II and III, the differences between the other levels were significant (p<0.05). There was a significant correlation between isometric force and isometric torque measurements of the neck extensor muscles at different levels (0.81
Conclusion:
Maximum isometric force and maximum isometric torque measurements of the neck extensor muscles vary with the length of the lever arm. It is recommended that a specific level of thoracic support should be used in follow-up and intervention studies. Setting the level of thoracic support at a specific level will make it possible to compare the strength of the neck extensor muscles in different studies. Measurements at the level of the spine of the scapula were easier and less time consuming.
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Muscles of the Thorax
The diaphragm is at the core of thoracic musculature, the primary muscle involved in breathing. This expansive, dome-shaped muscle marks the division between the thoracic and abdominal cavities. It originates...
Muscles that Move the Head
The bilateral sternocleidomastoid, or SCM, and the suprahyoid and infrahyoid muscles are significant head flexors. The SCM muscles originate at the sternum and clavicle and attach to the mastoid process of the temporal bone. The SCM contracts bilaterally to bend the head forward, whereas...
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...
Axial and Appendicular Muscles
Axial Muscles
Axial muscles, situated along the body's midline, are intricately connected to the axial skeleton, which includes the skull, spine, ribs, and sternum. These muscles facilitate facial expressions and play a...
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...

