Related Experiment Video
Updated: Jul 9, 2026

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Upper airway volume segmentation analysis using cine MRI findings in children with tracheostomy tubes
Bradley L Fricke1, M Bret Abbott, Lane F Donnelly
1Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati OH 45229, USA.
Objective:
The purpose of this study is to evaluate the airway dynamics of the upper airway as depicted on cine MRI in children with tracheotomy tubes during two states of airflow through the upper airway.
Materials And Methods:
Sagittal fast gradient echo cine MR images of the supra-glottic airway were obtained with a 1.5T MRI scanner on seven children with tracheotomy tubes. Two sets of images were obtained with either the tubes capped or uncapped. The findings of the cine MRI were retrospectively reviewed. Volume segmentation of the cine images to compare the airway volume change over time (mean volume, standard deviation, normalized range, and coefficient of variance) was performed for the capped and uncapped tubes in both the nasopharynx and hypopharynx (Signed Rank Test).
Results:
Graphical representation of the airway volume over time demonstrates a qualitative increased fluctuation in patients with the tracheotomy tube capped as compared to uncapped in both the nasopharyngeal and hypopharyngeal regions of interest. In the nasopharynx, the mean airway volume (capped 2.72 mL, uncapped 2.09 mL, p = 0.0313), the airway volume standard deviation (capped 0.42 mL, uncapped 0.20 mL, p = 0.0156), and the airway volume range (capped 2.10 mL, uncapped 1.09 mL, p = 0.0156) were significantly larger in the capped group of patients. In the hypopharynx, the airway volume standard deviation (capped 1.54 mL, uncapped 0.67 mL, p = 0.0156), and the airway volume range (capped 6.44 mL, uncapped 2.93 mL, p = 0.0156) were significantly larger in the capped tubes. The coefficient of variance (capped 0.37, uncapped 0.26, p = 0.0469) and the normalized range (capped 1.52, uncapped 1.09, p = 0.0313) were significantly larger in the capped tubes.
Conclusion:
There is a statistically significant change in airway dynamics in children with tracheotomy tubes when breathing via the airway as compared to breathing via the tracheotomy tube.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of the...
Respiratory Volumes and Capacities I
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Respiratory Volumes and Capacities
