Related Experiment Video

Updated: Jul 9, 2026

Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

Arm cavity resonant sideband control for laser interferometric gravitational wave detectors

D E McClelland, J B Camp, J Mason

    Optics Letters
    |December 13, 2007
    PubMed

    Abstract:

    We present a new optical control scheme for a laser interferometric gravitational wave detector that has a high degree of tolerance to interferometer spatial distortions and noise on the input light. The scheme involves resonating the rf sidebands in an interferometer arm cavity.

    More Related Videos

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
    12:14

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

    Published on: August 12, 2013

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
    07:55

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

    Published on: September 22, 2017

    Related Experiment Videos

    Last Updated: Jul 9, 2026

    Implementation of a Reference Interferometer for Nanodetection
    16:11

    Implementation of a Reference Interferometer for Nanodetection

    Published on: April 26, 2014

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry
    12:14

    The Generation of Higher-order Laguerre-Gauss Optical Beams for High-precision Interferometry

    Published on: August 12, 2013

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis
    07:55

    High-speed Continuous-wave Stimulated Brillouin Scattering Spectrometer for Material Analysis

    Published on: September 22, 2017

    Related Concept Videos

    Standing Waves in a Cavity01:28

    Standing Waves in a Cavity

    A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:

    Articles linked to this work by shared authors, journal, and citation graph.

    GW240925 and GW250207: Astrophysical Calibration of Gravitational Wave Detectors.

    Physical review letters·2026

    Loss-Tolerant Detection of Squeezed States in the 2 μm Region.

    Physical review letters·2026

    Black Hole Spectroscopy and Tests of General Relativity with GW250114.

    Physical review letters·2026

    GW250114: Testing Hawking's Area Law and the Kerr Nature of Black Holes.

    Physical review letters·2025

    Low-vibration cryogenic test facility for next generation of ground-based gravitational-wave observatories.

    The Review of scientific instruments·2025

    Squeezing the quantum noise of a gravitational-wave detector below the standard quantum limit.

    Science (New York, N.Y.)·2024

    Experimental demonstration of OCC-based optical over-the-air computation.

    Optics letters·2026

    High-power-flatness wavelength-tunable Er-doped fluoride fiber laser pumped at 1650 nm.

    Optics letters·2026

    Sub-5-nm-period metasurfaces for refractive-index-customized optics.

    Optics letters·2026

    Non-Hermitian engineering for low-loss terahertz transmission in a lithium niobate-on-silicon platform.

    Optics letters·2026

    Fabrication of tilted fiber Bragg gratings in all-cyclo olefin polymer fibers.

    Optics letters·2026

    Nanohole-assisted SiGe/Si phototransistor with high absorption efficiency.

    Optics letters·2026

    A Modified Palatal Island Flap Technique for Oroantral Fistula Closure: An Open-Route Approach.

    Journal of stomatology, oral and maxillofacial surgery·2026

    Perceptions of Secure Messaging and Patient Safety: Results of an Interprofessional Survey.

    Hospital pediatrics·2026

    CW-fDOT with a standard optical brain model: improving hemodynamic sensitivity and functional localization.

    Neurophotonics·2026

    Multimodal Wearable Sensor System for Continuous Peripheral Circulation Monitoring in Postoperative Flap Care.

    Advanced healthcare materials·2026

    Phase-stable transmission of broadband signals based on an MPPD-enabled optoelectronic phase-locked loop.

    Optics letters·2026

    Peak-transmittance-tunable multimode interference (MMI) coupler.

    Optics letters·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us