Analysis of basic compounds by reversed-phase high-performance liquid chromatography using hybrid inorganic/organic
Nicola H Davies1, Melvin R Euerby, David V McCalley
1Centre for Research in Biomedicine, University of the West of England, Frenchay, Bristol BS16 1QY, UK.
Abstract:
The retention and mass overload of five bases and a quaternary ammonium compound were studied on a bridged ethyl hybrid inorganic/organic phase (XBridge C18) over a pH range 2.7-12.0 using acetonitrile-phosphate and carbonate buffers. Some comparisons were drawn with results on a methyl hybrid (XTerra) phase. At low pH, rapid mass overload was observed with severe decreases in efficiency as sample mass was increased over the range 0.04-5 microg of solute. At intermediate pH (swpH 7.0), generally good peak shapes for small sample mass were still obtained on the ethyl hybrid, but with somewhat increased tailing of bases compared with swpH 2.7. At higher pH (swpH 10), good peak shape and improved loadability were obtained for moderately strong bases, due to their occurrence mostly as neutral species. However, stronger bases gave poor efficiency, attributed to interaction of the charged basic solute with increasingly ionised column silanol groups. Results were broadly similar on the methyl hybrid at swpH 10. At swpH 11, unusual profiles of increasing followed by decreasing efficiency were obtained on the ethyl hybrid for some bases as sample mass was increased; improved results were obtained at swpH 12. While the column loadability increased substantially at the highest pH studied, tailing for small sample mass was still more severe than at low pH, even though all compounds were <1% ionised in the mobile phase.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Ion-Exchange Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...