Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
The interscan variation of CT coronary artery calcification score: analysis of the Calcium Acetate Renagel Comparison
Matthew J Budoff1, Paul Kessler, Yan L Gao
1Los Angeles Biomedical Research Institute at Harbor UCLA, Torrance, CA 90502, USA. Budoff@ucla.edu
Rationale And Objectives:
In the Calcium Acetate Renagel Evaluation (CARE)-2 study, the effects of calcium acetate plus atorvastatin (Lipitor) on the progression of coronary artery calcifications (CACs) are evaluated versus those of Renagel, monitored using dual electron beam tomography (EBT) scans (two scans at study initiation and two at follow up). The aim of this study is to estimate the interscan variation for the Agatston score and for the volume score determined in patients with end-stage renal disease (ESRD) in the CARE-2 study.
Materials And Methods:
CAC score and volume were measured at study initiation in 463 ESRD subjects (mean age: 59.4 +/- 12.5 years, 48.3% female). All patients underwent dual scanning using an EBT, as first scan of two needed to measure the progression of CAC when treated with sevelamer (Renagel) compared with calcium acetate with or without atorvastatin. All scans in all participants were completed by using an EBT system (GE Imatron, South San Francisco, CA). Interscan variability was defined by the following formula: abs (scan A - scan B) / (0.5 x scan A + 0.5 x scan B) x 100%, where A and B denote the first and second scan, respectively, of the dual scan procedure performed before treatment. We evaluated the reproducibility of the cutpoints commonly used for calcium scores clinically, namely 1-30, 31-100, 101-400, and >400.
Results:
The CAC interscan variability was 11.8% using the Agatston score and 10.3% using the volume score. The reproducibility was then assessed using cutpoints 1-30, 31-100, 101-400, and >400. Agatston score variability for the four subgroups was 61.3%, 23%, 16.1%, and 8.2%, respectively (mean variability, 11.8%). Volume score variability was 60.0%, 14.4%, 14.6%, and 7.7%, respectively (mean variability, 10.3%). The correlation coefficient for scan A to scan B goes up significantly with increasing calcium scores and reaches 0.99 for scores greater than 400 (P < .0001).
Conclusion:
Interscan variability was sufficiently small for patients with calcium scores greater than 30. Our study thus demonstrates a sufficient reproducibility of the calcium score using EBT. This score allows for accurate serial assessment of these patients and for comparing different therapies.
More Related Videos
06:57Semi-Automatic Graphical Tool for Measuring Coronary Artery Spatially Weighted Calcium Score from Gated Cardiac Computed Tomography Images
Published on: September 22, 2023
08:02Novel Quantification Protocol for Cardiovascular Calcification Progression Using Longitudinal MicroPET/MicroCT Images
Published on: November 15, 2024
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...