Related Experiment Video
Updated: Jul 9, 2026

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Hemodynamic evaluation and monitoring in the ICU
1Department of Critical Care Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA 15213, USA. pinskymr@upmc.edu
Abstract:
Hemodynamic monitoring, a cornerstone in the management of the critically ill patient, is used to identify cardiovascular insufficiency, its probable cause, and response to therapy. Still it is difficult to document the efficacy of monitoring because no device improves outcome unless coupled to a treatment that improves outcome. Several clinical trials have consistently documented that preoptimization for high-risk surgery patients treated in the operating room and early (< 12 h) goal-directed resuscitation in septic patients treated in the emergency department reduce morbidity, mortality, and resource use (costs) when the end points of resuscitation were focused on surrogate measures of adequacy of global oxygen delivery (Do2). The closer the resuscitation is to the insult, the greater the benefit. When resuscitation was started after ICU admission in high-risk surgical patients, reduced length of stay was also seen. The focus of these monitoring protocols is to establish a mean arterial pressure > 65 mm Hg and then to increase Do2 to 600 mL/min/m2 within the first few minutes to hours of presentation. To accomplish these goals, hemodynamic monitoring focuses more on measures of cardiac output and mixed venous oxygen saturation to access adequacy of resuscitation efforts than on filling pressures. Although these protocols reduce mortality and morbidity is selected high-risk patient groups, the widespread use of monitoring-driven treatment protocols has not yet happened, presumably because all studies have been single-center trials using a single, proprietary blood flow-monitoring device. Multicenter trials are needed of early goal-directed therapies for all patients presenting in shock of various etiologies and when the protocol and not the monitoring device is the primary variable.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Rheumatic Heart Disease IV: Nursing Management
Dysrhythmias V: Evaluating Dysrhythmias
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Dysrhythmias VII: Nursing Management of Dysrhythmias

