Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Natural language processing tools for non-clinical healthcare management.

Journal of healthcare quality research·2023
Same author

Angiogenic imbalance in maternal and cord blood is associated with neonatal birth weight and head circumference in pregnancies with major fetal congenital heart defect.

Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology·2023
Same author

Luminescent and magnetic [TbEu] 2D metal-organic frameworks.

Dalton transactions (Cambridge, England : 2003)·2023
Same author

Biomedical image classification made easier thanks to transfer and semi-supervised learning.

Computer methods and programs in biomedicine·2020
Same author

Reduction of the Carbapenemase Inactivation Method (CIM) assay time by real-time PCR.

Journal of microbiological methods·2020
Same author

Coumarin-lanthanide based compounds with SMM behavior and high quantum yield luminescence.

Dalton transactions (Cambridge, England : 2003)·2020

Related Experiment Video

Updated: Jul 9, 2026

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
08:01

Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

Published on: November 21, 2019

Bidimensional planar micro-optics for optochemical absorbance sensing.

I Garcés, F Villuendas, J Subías

    Optics Letters
    |December 18, 2007
    PubMed
    Summary

    This study introduces a novel optochemical absorbance sensor using a planar micro-optic circuit and an active membrane. The device offers high sensitivity and fast response times for detecting specific compounds.

    More Related Videos

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
    08:12

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

    Published on: March 13, 2013

    Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers
    10:21

    Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers

    Published on: May 5, 2016

    Related Experiment Videos

    Last Updated: Jul 9, 2026

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures
    08:01

    Spectral and Angle-Resolved Magneto-Optical Characterization of Photonic Nanostructures

    Published on: November 21, 2019

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
    08:12

    Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

    Published on: March 13, 2013

    Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers
    10:21

    Multicolor Fluorescence Detection for Droplet Microfluidics Using Optical Fibers

    Published on: May 5, 2016

    Area of Science:

    • Optoelectronics
    • Chemical Sensing
    • Materials Science

    Background:

    • Optochemical sensors are crucial for detecting specific chemical compounds.
    • Existing sensor designs face limitations in sensitivity and response time.
    • Planar micro-optics offer potential for miniaturized and efficient sensor development.

    Purpose of the Study:

    • To present a new approach for developing optochemical absorbance sensors.
    • To demonstrate the integration of an optochemically active membrane within a planar micro-optic circuit.
    • To evaluate the sensitivity and response time of the developed sensor.

    Main Methods:

    • Fabrication of a planar micro-optic circuit.
    • Deposition of an optochemically active membrane onto the circuit.
    • Utilizing planar micro-optics components for optical field control.
    • Measuring potassium ion concentration as a proof of concept.

    Main Results:

    • The developed device confines the optical field effectively.
    • High sensitivity is achieved due to long light paths through the membrane.
    • Low response time is observed due to thin membrane diffusion.
    • Successful experimental verification of potassium concentration measurement.

    Conclusions:

    • The presented approach enables the development of highly sensitive and fast-responding optochemical absorbance sensors.
    • The integration of active membranes within planar micro-optic circuits is a viable strategy for chemical sensing.
    • This technology holds promise for specific absorbance sensing applications, as demonstrated by potassium detection.