Related Experiment Video
Updated: Jul 9, 2026

Early Detection of Drug-Induced Renal Hemodynamic Dysfunction Using Sonographic Technology in Rats
Published on: March 11, 2016
Renogram and deconvolution parameters in diagnosis of renal artery stenosis. Variants of background subtraction and
1Department of Clinical Physiology, Sjukhuset, SE-831 83 Ostersund, Sweden. viktor.kempi@jll.se
Aim:
Multivariate statistical methods can be used for objective analysis. The emphasis is on analysing renal function parameters together, not one at a time. The aim is to identify curve parameters useful in making predictions in kidneys with and without renal artery stenosis (RAS).
Patients, Methods:
68 patients with resistant hypertension were subjected to captopril renography with (99m)Tc-DTPA. Variants of background areas and background subtraction methods were employed. A correction was applied for loss of renal parenchyma. Parameters from time-activity curves and retention curves from deconvolution were calculated. Renal angiography established the presence or absence of RAS. Logistic regression analysis, using age- and kidney size-adjusted models, was performed to assess the capability of renography and deconvolution to differentiate between kidneys with and without RAS.
Results:
Discrimination between normal kidneys and RAS was achieved by deconvolution and by renography. Deconvolution was the method of first rank with a sensitivity of 87% and a specificity of 98%. For separation of RAS and kidneys with parenchymal insufficiency deconvolution was the method of first rank with a sensitivity of 80 % and specificity of 89 %, whereas renography produced poor results.
Conclusion:
The best performance with (99m)Tc-DTPA was based on normalised background subtraction using a rectangular area between the kidneys. Deconvolution produced the most favourable results in the separation of kidneys with and without RAS. For separation of RAS and kidneys with parenchymal insufficiency conventional renography produced poor results. Conceptually, the results of a logistic regression analysis of renal function parameters may raise possibilities in the field of computer-aided diagnosis.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
06:51Multilevel Microdissection and Functional-Structural Profiling of Human Renal Arterial Branches
Published on: September 5, 2025
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Ultrasonography