Doppler Optical Coherence Tomography of Retinal Circulation
Published on: September 18, 2012
The clinical utility of dynamic contour tonometry and ocular pulse amplitude
Jennifer S Weizer1, Sanjay Asrani, Sandra S Stinnett
1Duke University Eye Center, Durham, NC, USA. jweizer@unmich.edu
Purpose:
To determine if ocular pulse amplitude (OPA) as measured by dynamic contour tonometry (DCT) is related to severity of glaucoma, and if intraocular pressure (IOP) as measured by DCT is related to central corneal thickness (CCT).
Methods:
Patients were selected from the Duke Eye Center glaucoma clinic. Fifty-five eyes of 32 patients were included; right and left eyes were analyzed separately. CCT, OPA, DCT IOP, Goldmann applanation tonometry (GAT), Tonopen applanation tonometry (TAT), and systemic blood pressure were measured. Advanced Glaucoma Intervention Study score and mean deviation of visual field, and vertical and horizontal cup-disc ratios were recorded in a masked manner. Descriptive statistics were obtained, and OPA, DCT IOP, GAT, and TAT underwent univariate analyses to assess for relationships with predictor variables.
Results:
OPA, DCT IOP, GAT, and TAT were positively associated with CCT and with having no surgical intervention for right and left eyes, and were negatively associated with vertical and horizontal cup-disc ratios.
Conclusions:
Increased OPA seems to correlate with less severe glaucoma and with increased CCT. DCT IOP seems to be affected by CCT along with GAT and TAT.
Related Concept Videos
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse
The pulse serves as a clinical indicator...