Related Experiment Video
Updated: Jul 9, 2026

Subcutaneous Infection of Methicillin Resistant Staphylococcus Aureus (MRSA)
Published on: February 9, 2011
Venous thrombosis in patients with short- and long-term central venous catheter-associated Staphylococcus aureus
Anna Lisa Crowley1, Gail E Peterson, Daniel K Benjamin
1Division of Cardiology, Department of Medicine, Duke University Medical Center, Durham, NC, USA. annalisa.crowley@duke.edu
Objective:
Infection and thrombosis are important complications of intravascular catheters. The purpose of this study was to determine the incidence of thrombosis in patients with central venous catheter-associated Staphylococcus aureus bacteremia and the utility of physical examination for diagnosing upper extremity or neck venous thrombosis.
Design:
Prospective observational cohort.
Setting:
Tertiary care facility.
Patients:
In all, 65 consecutive patients with catheter-associated S. aureus bacteremia with central venous catheters of the internal jugular, brachial, or subclavian veins were eligible for participation.
Intervention:
From July 1999 through August 2004, enrolled patients underwent physical examination and ultrasonography independently to identify the presence of catheter-associated thrombosis. Study ultrasonograms were interpreted blindly using defined criteria. Outcomes were defined at 12-wk follow-up.
Measurements And Main Results:
A total of 48 patients were enrolled. By ultrasonography, definite or possible thrombosis was present in 34 of 48 patients (71%) in this cohort. Death or recurrent bacteremia occurred in 11/34 (32%) infected patients with thrombosis and two of 14 (14%) infected patients without thrombosis (p = .29). Sensitivity of all physical examination findings, either alone or in combination, was low (< or = 24%). Only engorged veins upon hand elevation and the presence of multiple physical examination abnormalities were specific (100% each).
Conclusions:
Thrombosis is a common complication of central venous catheter-associated S. aureus bacteremia. Patients with central venous catheter-associated S. aureus bacteremia should undergo ultrasonography to detect thromboses even if the physical examination is normal.
Related Concept Videos
Staphylococcal Skin Infections
Venous Thrombosis I: Introduction
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Thrombosis IV: Nursing Management
Endocarditis I: Introduction