Pulse contour analysis: a valid assessment of central arterial stiffness in children?

Giacomo D Simonetti1, Ute Eisenberger, Ivo P Bergmann

  • 1Division of Paediatric Nephrology, Children's Hospital, University of Bern, Berne, Switzerland.

Insights

Pulse contour analysis shows potential for assessing arterial stiffness in children. However, digital volume pulse analysis has limitations compared to pulse wave velocity, especially in individuals with high vascular tone.

Area of Science:

  • Cardiovascular Physiology
  • Pediatric Cardiology
  • Biomedical Engineering

Background:

  • Peripheral pressure wave contour analysis in adults correlates with central aortic stiffness.
  • Assessing large artery stiffness in children is crucial for early cardiovascular risk identification.

Purpose of the Study:

  • To evaluate the appropriateness of pulse contour analysis for assessing large artery stiffness in healthy children.
  • To compare digital volume pulse analysis with pulse wave velocity (PWV) in pediatric populations.

Main Methods:

  • Digital volume pulse (DVP) analysis and carotid-femoral pulse wave velocity (cf-PWV) were simultaneously measured in 79 healthy children (8-15 years).
  • Stiffness index (SI) was calculated using DVP, and cf-PWV was determined.
  • Data from 42 healthy adults served as a control group for SI comparison.

Main Results:

  • Childhood SI values aligned with expected age-extrapolated adult values.
  • Childhood SI positively correlated with cf-PWV (r²=0.07, P=0.02) but not with blood pressure.
  • Excluding participants with high vascular tone (Reflexion Index > 90%) improved the SI-PWV correlation (r²=0.13, P=0.001).

Conclusions:

  • Digital volume pulse analysis demonstrates limitations in measuring arterial stiffness in children compared to cf-PWV.
  • High vascular tone can significantly impact the reliability of DVP-based arterial stiffness assessment in pediatric subjects.

Related Concept Videos

Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse01:11

Assessment of radial pulse

Assessment of Radial Pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Assessment of apical pulse01:17

Assessment of apical pulse

Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...