Differences in solute removal by two high-flux membranes of nominally similar synthetic polymers

Rosemary Ouseph1, Colin A Hutchison, Richard A Ward

  • 1Kidney Disease Program, University of Louisville, 615 S. Preston Street, Louisville, KY 40202-1718, USA.

Abstract

Related Concept Videos

Osmosis and Osmotic Pressure of Solutions02:40

Osmosis and Osmotic Pressure of Solutions

A number of natural and synthetic materials exhibit selective permeation, meaning that only molecules or ions of a certain size, shape, polarity, charge, and so forth, are capable of passing through (permeating) the material. Biological cell membranes provide elegant examples of selective permeation in nature, while dialysis tubing used to remove metabolic wastes from blood is a more simplistic technological example. Regardless of how they may be fabricated, these materials are generally...
Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or basic...
Osmotic Pressure01:26

Osmotic Pressure

Osmosis is a process where solvent molecules move toward a solution through a semipermeable membrane. As the solution dilutes due to the entry of solvent, it expands. This expansion increases the hydrostatic pressure of the solution. When the hydrostatic pressure equals the osmotic pressure, osmosis stops.Osmotic pressure, denoted by Π, is the minimum pressure needed to prevent the solvent from passing into the solution by osmosis. The van 't Hoff equation calculates the osmotic pressure of an...
Determination of Molar Masses of Polymers II01:27

Determination of Molar Masses of Polymers II

Polymer samples typically consist of macromolecular chains with a distribution of lengths, resulting in a range of molar masses rather than a single discrete value. Conventional descriptors such as the number-average molar mass and weight-average molar mass quantify this distribution but do not fully capture polymer behavior in solution..The viscosity-average molar mass provides a more realistic description of polymer behavior in solution because it accounts for the enhanced contribution of...
Detergent Purification of Membrane Proteins01:18

Detergent Purification of Membrane Proteins

Detergents are used to purify the integral proteins of the membrane. The hydrophobic portion of the detergent can replace membrane phospholipids while solubilizing the membrane proteins. When detergent monomers reach a specific concentration in a solution called critical micelle concentration (CMC), they form micelles. Above CMC, the concentration of the detergent monomers remains in equilibrium with the micelle. The number of detergent monomers present in the CMC varies for each detergent, and...