Related Experiment Video
Updated: Jul 8, 2026

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Human touch vs. axillary digital thermometry for detection of neonatal hypothermia at community level
Siddharth Agarwal1, Vani Sethi, Ravindra Mohan Pandey
1Urban Health Resource Centre, New Delhi 110057, India.
We examined the diagnostic accuracy of human touch (HT) method in assessing hypothermia against axillary digital thermometry (ADT) by a trained non-medical field investigator (who supervised activities of community health volunteers) in seven villages of Agra district, Uttar Pradesh, India. Body temperature of 148 newborns born between March and August 2005 was measured at four points in time for each enrolled newborn (within 48 h and on days 7, 30 and 60) by the field investigator under the axilla using a digital thermometer and by HT method using standard methodology. Total observations were 533. Hypothermia assessed by HT was in agreement with that assessed by ADT (<36.5 degrees C) in 498 observations. Hypothermia assessed by HT showed a high diagnostic accuracy when compared against ADT (kappa 0.65-0.81; sensitivity 74%; specificity 96.7%; positive predictive value 22; negative predictive value 0.26). HT is a simple, quick, inexpensive and programmatically important method. However, being a subjective assessment, its reliability depends on the investigator being adequately trained and competent in making consistently accurate assessments. There is also a need to assess whether with training and supervision even the less literate mothers, traditional birth attendants and community health volunteers can accurately assess mild and moderate hypothermia before promoting HT for early identification of neonatal risk in community-based programs.
We examined the diagnostic accuracy of human touch (HT) method in assessing hypothermia against axillary digital thermometry (ADT) by a trained non-medical field investigator (who supervised activities of community health volunteers) in seven villages of Agra district, Uttar Pradesh, India. Body temperature of 148 newborns born between March and August 2005 was measured at four points in time for each enrolled newborn (within 48 h and on days 7, 30 and 60) by the field investigator under the axilla using a digital thermometer and by HT method using standard methodology. Total observations were 533. Hypothermia assessed by HT was in agreement with that assessed by ADT (<36.5 degrees C) in 498 observations. Hypothermia assessed by HT showed a high diagnostic accuracy when compared against ADT (kappa 0.65-0.81; sensitivity 74%; specificity 96.7%; positive predictive value 22; negative predictive value 0.26). HT is a simple, quick, inexpensive and programmatically important method. However, being a subjective assessment, its reliability depends on the investigator being adequately trained and competent in making consistently accurate assessments. There is also a need to assess whether with training and supervision even the less literate mothers, traditional birth attendants and community health volunteers can accurately assess mild and moderate hypothermia before promoting HT for early identification of neonatal risk in community-based programs.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...