Related Experiment Video
Updated: Jul 8, 2026

A Volumetric Method for Quantification of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage
Published on: July 28, 2018
Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar
Minsuok Kim1, Elad I Levy, Hui Meng
1Department of Mechanical and Aerospace Engineering, University at Buffalo, State University of New York, Buffalo, New York, USA.
Objective:
The porous intravascular stents that are currently available may not cause complete aneurysm thrombosis and may therefore fail to provide durable protection against aneurysm rupture when used as a sole treatment modality. The goal of this study was to quantify the effects of porous stents on aneurysm hemodynamics using computational fluid dynamics.
Methods:
The geometry of a wide-necked saccular basilar trunk aneurysm was reconstructed from a patient's computed tomographic angiography images. Three commercial stents (Neuroform2; Boston Scientific/Target, San Leandro, CA; Wingspan; Boston Scientific, Fremont, CA; and Vision; Guidant Corp., Santa Clara, CA) were modeled. Various combinations of one to three stents were virtually conformed to fit into the vessel lumen and placed across the aneurysm orifice. An unstented aneurysm served as a control. Computational fluid dynamics analysis was performed to calculate the hemodynamic parameters considered important in aneurysm pathogenesis and thrombosis for each of the models.
Results:
The complex flow pattern observed in the unstented aneurysm was suppressed by stenting. Stent placement lowered the wall shear stress in the aneurysm, and this effect was increased by additional stent deployment. Turnover time was moderately increased after single- and double-stent placement and markedly increased after three stents were placed. The influence of stent design on hemodynamic parameters was more significant in double-stented models than in other models.
Conclusion:
Aneurysm hemodynamic parameters were significantly modified by placement of multiple stents. Because the associated modifications may be helpful as well as harmful in terms of rupture risk, use of this technique requires careful consideration.
More Related Videos
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
07:21Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices
Published on: September 8, 2023