Endotoxemia increases the clearance of mPEGylated 5000-MW quantum dots as revealed by multiphoton microvascular

Ryon M Bateman1, Kevin C Hodgson, Kapil Kohli

  • 1University of British Columbia, Critical Care Research Laboratories, James Hogg iCAPTURE Centre, St. Paul's Hospital, Vancouver, British Colombia, Canada, V6Z 1Y6. rbateman@mrl.ubc.ca

Insights

Quantum dots and multiphoton microscopy enable deep microcirculation imaging in mice. Activated immune cells increase quantum dot uptake, affecting clearance rates during endotoxemia.

Area of Science:

  • Biomedical Engineering
  • Microscopy
  • Nanotechnology

Background:

  • Assessing microcirculation is crucial for life-threatening conditions.
  • Imaging deep tissues is challenging due to light absorption and scattering.

Purpose of the Study:

  • To develop a method for imaging deep microcirculation in vivo.
  • To utilize quantum dots for enhanced contrast in multiphoton microscopy.

Main Methods:

  • Laser scanning multiphoton microscopy was employed.
  • Methoxy-PEGylated quantum dots (655-nm, 5000-MW) were used as fluorescent probes.
  • Imaging was performed in mouse hind limb skeletal muscle at depths of 150-200 microm.

Main Results:

  • Complete 3-D microvascular units were visualized, including arterioles, capillaries, and venules.
  • Quantum dots accumulated at microvascular bifurcations and extravasated during an endotoxemic model.
  • Quantum dot clearance was significantly faster in endotoxemic mice (1.6 h⁻¹) compared to normal conditions (0.23 h⁻¹).
  • Activated monocytes showed increased non-specific uptake of quantum dots in vitro.

Conclusions:

  • Quantum dots combined with multiphoton microscopy offer excellent contrast for deep microvascular imaging.
  • The study provides insights into quantum dot behavior in microcirculation during inflammatory responses.
  • This technique has potential for diagnosing and monitoring diseases affecting microvasculature.