Noninvasive cardiac output determination using applanation tonometry-derived radial artery pulse contour analysis in
Friederike Compton1, Marc Wittrock, Juergen-Heiner Schaefer
1Division of Nephrology, Department of Nephrology and Endocrinology, Charité University Medicine Berlin, Campus Benjamin Franklin, Germany. friederike.compton@charite.de
Abstract:
Conventional thermodilution cardiac output (CO) monitoring is limited mainly to intensive care units and operating rooms because it requires the use of invasive techniques. To reduce the potential for complications and to broaden the applicability of hemodynamic monitoring, noninvasive methods for CO determination are being sought. Applanation tonometry allows noninvasive CO estimation through pulse contour analysis, but the method has not been evaluated in critically ill patients. We therefore performed noninvasive radial artery applanation tonometry in 49 critically ill medical intensive care unit patients and compared CO estimates to invasive CO measurements obtained using a pulmonary artery catheter or the PiCCO transpulmonary thermodilution system. One-hundred-sixteen measurements were performed, and patients were receiving vasopressor support during 78 measurements. When the data were analyzed with bias and precision statistics, a large bias of 2.03 L x min(-1) x m(-2) and a high percentage error of 85% were found between the invasive measurements and applanation tonometry-derived CO estimates, with the noninvasive CO results being significantly lower than the invasive ones (P < 0.001). There was no significant difference in bias between the patients who were receiving vasopressor support and those who were not (P = 0.874) or between patients with good and poor applanation tonometry pressure waveform signal quality (P = 0.071). Whereas a significant increase in the invasively determined CO was observed when a fluid bolus was administered (n = 7, P = 0.016), these changes were not reflected by the noninvasive method. We conclude that radial artery applanation tonometry is not suitable to determine CO in critically ill hemodynamically unstable patients.
More Related Videos
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Special considerations while measuring pulse
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...