Aims:
Small elevations in troponin T levels have been shown with limited radiofrequency (RF) ablation procedures for supraventricular tachycardia, usually to levels below the threshold for ischaemia or infarction. Left atrial catheter ablation for atrial fibrillation (AF) requires far more RF energy, therefore could be expected to have greater elevation in troponin T. We determined troponin T levels before and after ablation in these patients to evaluate the amount of rise with this ablation.
Methods:
All patients undergoing pulmonary vein isolation (PVI) from May 2004 to October 2004 had troponin T levels measured 4 h following completion of the procedure. The first 30 patients also had a troponin T level measured 1 h prior to PVI to establish a baseline reference.
Results:
Sixty patients were studied, with 81.7% males and a mean age of 54.6 +/- 9.9 years. No patient had underlying structural heart disease. The baseline troponin T level was normal (<0.01 microg/L) in all 30 patients. Post-procedure troponin T levels were elevated in all 60 patients compared with baseline (P < 0.05), with a mean level of 0.85 microg/L and a range of 0.26-1.57 microg/L after an average RF ablation time of 56 +/- 15 min. All levels were above the reference range for diagnosis of acute myocardial infarction (>0.15 microg/L). Troponin T level was not related to the number of RF lesions, RF time, procedure time, or associated external cardioversion.
Conclusions:
Troponin T elevations occurred in all patients undergoing PVI, to levels at least 20 times the normal concentration, into the range for diagnosis of acute myocardial infarction. Therefore, troponin T would not be specific for ischaemia in the setting of chest pain post-catheter ablation for AF.
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Cardiopulmonary Resuscitation III: AED Use
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization III: Left Heart Catheterization
Cardiopulmonary Resuscitation IV: Pharmacological Management