Arsenic speciation and identification of monomethylarsonous acid and monomethylthioarsonic acid in a complex matrix
Santha Ketavarapu V Yathavakilla1, Michael Fricke, Patricia A Creed
1Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, USA.
Abstract:
Anion-exchange chromatography was utilized for speciation of arsenite (As(III)), arsenate (As(V)), dimethylarsinic acid (DMA(V)), monomethylarsonic acid (MMA(V)), monomethylarsonous acid (MMA(III)), and the new As species monomethylthioarsonic acid (MMTA), using inductively coupled plasma mass spectrometric (ICPMS) detection. MMA(III) and MMTA were identified for the first time in freeze-dried carrot samples that were collected over 25 years ago as part of a joint U.S. EPA, U.S. FDA, and USDA study on trace elements in agricultural crops. The discovery of MMA(III) and MMTA in terrestrial foods necessitated the analytical characterization of synthetic standards of both species, which were used for standard addition in carrot extracts. The negative ion mode, high-resolution electrospray mass spectrometry (HR-ESI-MS) data produced molecular ions of m/z 122.9418 and 154.9152 for MMA(III) and MMTA, respectively. However, ESI-MS was not sensitive enough to directly identify MMA(III) and MMTA in the carrot extracts. Therefore, to further substantiate the identification of MMA(III) and MMTA, two additional separations using an Ion-120 column were developed using the more sensitive ICPMS detection. The first separation used 20 mM tetramethylammonium hydroxide at pH 12.2 with MMA(III) eluting in less than 7 min. In the second separation, MMTA eluted at 11.2 min by utilizing 40 mM ammonium carbonate at pH 9.0. Oxidation of MMA(III) and MMTA to MMA(V) with hydrogen peroxide was observed for standards and carrot extracts alike. Several samples of carrots collected from local markets in 2006 were also analyzed and found to contain low levels of inorganic arsenic species.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Interference
Qualitative Analysis
For instance, group IV...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Precipitation and Co-precipitation
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences