Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
Acute Coronary Syndrome III: Diagnostic Studies01:30

Acute Coronary Syndrome III: Diagnostic Studies

Diagnosing acute coronary syndrome or ACS begins with a thorough patient history. Notable symptoms include central, crushing chest pain radiating to the left arm, neck, jaw, or back, along with shortness of breath, sweating (diaphoresis), nausea, vomiting, dizziness, and palpitations.It is crucial to note any history of cardiac illnesses and assess risk factors, including age, gender, smoking, hypertension, diabetes, hyperlipidemia, and a sedentary lifestyle.During physical examination, vital...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT01:25

Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT

Calcium-Scoring CT ScanA calcium-scoring CT scan, also known as coronary artery calcium (CAC) scan, detects calcium deposits in the coronary arteries. This test assesses the risk of coronary artery disease (CAD), which can lead to cardiovascular events such as angina, heart failure, and sudden cardiac arrest.A calcium-scoring CT scan is generally recommended for individuals at intermediate risk of CAD without symptoms. It includes:Men aged 40-75 and women aged 50-75: Especially those with a...
Imaging Studies for Cardiovascular System II:Types of Echocardiography01:20

Imaging Studies for Cardiovascular System II:Types of Echocardiography

Echocardiography plays a role in assessing cardiac health and detecting heart conditions, with various types providing critical insights for diagnosis and treatment.
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Radiological Investigation III: Pulmonary Angiogram and PET Scan01:13

Radiological Investigation III: Pulmonary Angiogram and PET Scan

Radiological investigations are paramount in the diagnosis and management of various pulmonary diseases. Two essential investigations are the Pulmonary Angiogram and the Positron Emission Tomography (PET) Scan.
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization II: Right Heart Catheterization01:21

Cardiac Catheterization II: Right Heart Catheterization

Right Heart Catheterization: An OverviewRight heart catheterization is an invasive diagnostic procedure that measures right-sided cardiac and pulmonary artery pressures, calculates cardiac output, and identifies intracardiac shunts. It provides detailed hemodynamic data essential for diagnosing and managing various cardiovascular conditions, such as pulmonary hypertension.Access SitesCommon access sites for right heart catheterization include the internal jugular vein in the neck region, the...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Diagnostic performance of computed tomography-derived fractional flow reserve in patients with significant coronary artery stenosis.

Radiologia·2026
Same author

Diabetes and ischemia in stress perfusion cardiac magnetic resonance are comparable risk factors for cardiovascular events.

Radiologia·2025
Same author

Presentation of the series 'Advances in cardiac imaging'.

Radiologia·2025
Same author

Magnetic resonance in patients with cardiovascular devices. SEC-GT CRMTC/SEC-Heart Rhythm Association/SERAM/SEICAT consensus document.

Radiologia·2023
Same author

Low-dose chest CT for preoperative screening for SARS-CoV-2 infection.

Radiologia·2022
Same author

[Low-dose chest CT for preoperative screening for SARS-CoV-2 infection].

Radiologia·2022

Related Experiment Video

Updated: Jul 8, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

[Dual-source CT coronary angiography].

G Bastarrika1, M Arraiza, J Pueyo

  • 1Servicio de Radiología, Clínica Universitaria, Facultad de Medicina, Universidad de Navarra, Pamplona. bastarrika@unav.es

Revista De Medicina De La Universidad De Navarra
|January 11, 2008
PubMed
Summary

Dual-source computed tomography (DSCT) provides excellent coronary artery imaging regardless of heart rate, overcoming limitations of multidetector computed tomography (MDCT). This technique ensures high-quality scans even with elevated or irregular heart rhythms.

More Related Videos

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:59

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation

Published on: June 3, 2018

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
09:49

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization

Published on: December 2, 2013

Related Experiment Videos

Last Updated: Jul 8, 2026

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
09:32

Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging

Published on: December 9, 2021

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
06:59

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation

Published on: June 3, 2018

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
09:49

Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization

Published on: December 2, 2013

Area of Science:

  • Cardiovascular imaging
  • Radiology
  • Medical diagnostics

Background:

  • Multidetector computed tomography (MDCT) is valuable for non-invasive coronary artery assessment.
  • Limitations of 64-slice MDCT include challenges with high heart rates and irregular rhythms.
  • Beta-blocker administration is often required to manage heart rate for MDCT.

Observation:

  • Dual-source computed tomography (DSCT) was evaluated in three subjects with elevated heart rates and irregular heart rhythms.
  • DSCT imaging quality was assessed in these challenging patient cases.
  • Conventional 64-row-MDCT may face limitations in similar scenarios.

Findings:

  • DSCT enables coronary artery studies with excellent diagnostic quality.
  • Image quality is maintained independently of the patient's heart rate.
  • The need for beta-blockers is eliminated with DSCT, simplifying the imaging process.

Implications:

  • DSCT offers a superior alternative for coronary artery imaging in patients with high or irregular heart rates.
  • This technique enhances diagnostic confidence and patient comfort by avoiding medication.
  • DSCT expands the utility of computed tomography for comprehensive cardiovascular evaluation.