Related Experiment Videos
A randomized, double-blind, crossover design study of sevelamer hydrochloride and sevelamer carbonate in patients on
J Delmez1, G Block, J Robertson
1Washington University School of Medicine, St. Louis, MO 63110, USA. jdelmez@wustl.edu
Aims:
Sevelamer carbonate is an anion exchange resin with the same polymeric structure as sevelamer hydrochloride in which carbonate replaces chloride as the anion. The study investigated the effects of sevelamer carbonate and sevelamer hydrochloride on serum phosphorus, lipids and bicarbonate levels in hemodialysis patients.
Materials And Methods:
This was a double-blind, randomized, crossover study. 79 hemodialysis patients were randomly assigned to either sevelamer carbonate or sevelamer hydrochloride for 8 weeks followed by a crossover to the other regimen for an additional 8 weeks of treatment.
Results:
The mean serum phosphorus was 4.6+/-0.9 and 4.7+/-0.9 mg/dl during sevelamer carbonate and sevelamer hydrochloride treatment, respectively. Sevelamer carbonate and sevelamer hydrochloride were equivalent in controlling serum phosphorus, the geometric least square mean ratio was 0.99 (90% CI, 0.95-1.03). Mean total and LDL cholesterol were 144.0+/-33.9 and 59.5+/-24.9 mg/dl, respectively, during sevelamer carbonate treatment and 139.0+/-33.6 and 56.0+/-23.3 mg/dl, respectively, during sevelamer hydrochloride treatment. Serum bicarbonate levels increased by 1.3+/-4.1 mEq/l during sevelamer carbonate treatment. There were fewer gastrointestinal adverse events with sevelamer carbonate.
Conclusions:
Sevelamer carbonate and sevelamer hydrochloride were equivalent in controlling serum phosphorus and serum bicarbonate levels increased with sevelamer carbonate. Lipid profiles for both were well-below the levels suggested by KDOQI. Sevelamer carbonate may have advantages over sevelamer hydrochloride in the treatment of hyperphosphatemia in hemodialysis patients.
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
Bioavailability Study Design: Single Versus Multiple Dose Studies
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Hemodialysis II: Procedure and Complications