[Oximetry, fetal ECG and Oxford monitoring (compared to scalp pH)]
B Langer1, C Vayssière, G Fritz
1Département de Gynécologie-Obstétrique, Hôpital de Hautepierre, Strasbourg Cedex, France. bruno.langer@chru-strasbourg.fr
Continuous labor surveillance by fetal heart rate monitoring (FHR) is highly sensible but has a poor sensitivity. Fetal scalp pH testing has, therefore, been added to overcome this lack of sensitivity (cf. Bruno Carbonne). Later, other methods were introduced. After being initially promising, fetal oxymetry, developed by Nellcor, was evaluated by five randomized studies "of varying quality". These studies showed no decrease in caesarean section and operative extraction rate or metabolic acidosis. Fetal electrocardiogram (STAN) was studied in four randomized trials. Added to continuous FHR monitoring, STAN does not reduce caesarean section or operative extraction rates compared to FHR monitoring added to fetal scalp pH testing. However, it decreases the frequency of fetal scalp pH testing. There is no comparative trial on the computerized FHR monitoring using the Oxford System.
Continuous labor surveillance by fetal heart rate monitoring (FHR) is highly sensible but has a poor sensitivity. Fetal scalp pH testing has, therefore, been added to overcome this lack of sensitivity (cf. Bruno Carbonne). Later, other methods were introduced. After being initially promising, fetal oxymetry, developed by Nellcor, was evaluated by five randomized studies "of varying quality". These studies showed no decrease in caesarean section and operative extraction rate or metabolic acidosis. Fetal electrocardiogram (STAN) was studied in four randomized trials. Added to continuous FHR monitoring, STAN does not reduce caesarean section or operative extraction rates compared to FHR monitoring added to fetal scalp pH testing. However, it decreases the frequency of fetal scalp pH testing. There is no comparative trial on the computerized FHR monitoring using the Oxford System.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...


