Related Experiment Video
Updated: Jul 8, 2026

Bridging the Technology Divide in the COVID-19 Era: Using Virtual Outreach to Expose Middle and High School Students to Imaging Technology
Published on: September 28, 2022
A filmless radiology teaching conference system for pertinent displaying and image searching
Katsumi Abe1, Mitsuhiro Narata, Ikue Tanaka
1Department of Radiology, Nihon University School of Medicine, 30-1 Oyaguchi kami-cho, Itabashi-ku, Tokyo, 173-8610, Japan. akatsumi@med.nihon-u.ac.jp
Abstract:
To solve the problems of image displays in filmless radiology conferences for the purpose of teaching, we made an experimental design of a conference system with dual 50-in. plasma monitors for displaying larger images and a shared folder containing shortcuts to images for quick display during conferences on the desktop of each client computer in a picture archival and communication system. The image quality of the monitors was evaluated using the TG18-QC test pattern. The display time of images was measured in 20 cases when the shared folder was used and when it was not. Monitor screen size and image quality, operability, display time of images, and overall impression given by the system were evaluated subjectively by five radiologists. Although the image quality of the monitor was not as high as that of the high-resolution monitors used for diagnostic radiology, its performance was good enough for teaching. The average display time using the shared folder (2.6 +/- 0.39 s) was significantly shorter than without it (16.9 +/- 5.04 s; p = 2.85 x 10(-6)). Despite the need for certain improvements in monitor size and in the operability of the system, the radiologists considered the system suitable for radiology teaching conferences. We believe that this system is useful for institutions that intend to introduce a filmless system for filmless radiology teaching conferences.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies I: Kidney, Ureter, and Bladder Studies
