Related Experiment Video
Updated: Jul 8, 2026

Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Filters reduce the risk of bacterial transmission from contaminated heated humidifiers used with CPAP for obstructive
Girolamo A Ortolano1, Jeffrey Schaffer, Morven B McAlister
1Pall Corporation, East Hills, NY 11548, USA. Jerry_Ortolano@pall.com
Rationale:
The treatment of choice for obstructive sleep apnea (OSA) is nasal continuous positive airway pressure (nCPAP) during sleep, but dryness of the upper airway compromises compliance. Heated humidifiers may mitigate such noncompliance; however, recent observations suggest that their use, particularly if not cleaned, increases the risk of respiratory infections. Humidifier water may be contaminated, but the long-held view that passive humidifiers cannot aerosolize water may obscure the perception of risk of infection.
Objectives:
This study challenges the long-held view that "passover" humidifiers do not aerosolize water. With such evidence, this study characterizes the performance of filters to reduce the potential risk of contamination.
Methods:
Heated humidifier water contaminated with bacteria was studied under conditions simulating week-long use of nCPAP for OSA.
Results:
Bacteria were recovered in 9 of 11 tests from the breathing tubes of CPAP devices fitted with heated humidifiers with water contaminated with Brevundimonas diminuta or Serratia marcescens. Recoverable bacteria ranged from tens to thousands of colony forming units when tested at air flow rates of 60 liters per minute for 90 minutes. Neither organism was recovered from the circuit tubing when a hydrophobic breathing-circuit filter was positioned between the humidifier and face-mask tubing with a commercially available nCPAP machine tested under simulated-use conditions.
Conclusion:
Data suggest that patients with OSA being treated with nCPAP fitted with humidifiers may be aerosolizing bacteria, putting them at risk for developing respiratory infections and that the use of a hydrophobic filter may attenuate the passage of microbes from contaminated humidifier water.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Sleep Apnea
The condition is more prevalent among...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...