Effects of placement, attachment, and weight classification on pedometer accuracy
Susan Vincent Graser1, Robert P Pangrazi, William J Vincent
1Brigham Young University, 249G SFH, Provo, UT, USA.
Background:
The purpose was to determine if waist placement of the pedometer affected accuracy in normal, overweight, and obese children, when attaching the pedometer to the waistband or a belt.
Methods:
Seventy-seven children (ages 10-12 years) wore 5 pedometers on the waistband of their pants and a belt at the following placements: navel (NV), anterior midline of the right thigh (AMT), right side (RS), posterior midline of the right thigh (PMT), and middle of the back (MB). Participants walked 100 steps on a treadmill at 80 m x min(-1).
Results:
The RS, PMT, and MB sites on the waistband and the AMT and RS sites on the belt produced the least error.
Conclusions:
Of these sites, the RS placement is recommended because of the ease of reading the pedometer during activity. Using a belt did not significantly improve accuracy except for normal weight groups at the NV placement site.