1U.S. Department of Agriculture, Agricultural Research Service, Eastern Regional Research Center, 600 E. Mermaid Lane, Wyndmoor, PA 19038, USA. Lihan.Huang@ars.usda.gov
Abstract:
The objective of this research was to develop an infrared pasteurization process with automatic temperature control for inactivation of surface-contaminated Listeria monocytogenes on ready-to-eat meats such as hotdogs. The pasteurization system contained 4 basic elements: an infrared emitter, a hotdog roller, an infrared sensor, and a temperature controller. The infrared sensor was used to monitor the surface temperature of hotdogs while the infrared emitter, modulated by a power controller, was used as a heating source. The surface temperature of hotdogs was increased to set points (70, 75, 80, or 85 degrees C), and maintained for bacterial kill. The infrared surface pasteurization was evaluated using hotdogs that were surface-inoculated with a 4-strain L. monocytogenes cocktail to an average initial inoculum of 7.32 log (CFU/g). On the average 1.0, 2.1, 3.0, or 5.3 log-reduction in L. monocytogenes was observed after the surface temperature of hotdogs was increased to 70, 75, 80, or 85 degrees C, respectively. Holding the sample temperature led to additional bacterial inactivation. With a 3 min holding at 80 degrees C or 2 min at 85 degrees C, a total of 6.4 or 6.7 logs of L. monocytogenes were inactivated. This study demonstrated that the infrared surface pasteurization was effective in inactivating L. monocytogenes in RTE meats.
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Controlling Food Spoilage
Pasteurization and Food Preservation
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...