Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

X-ray Crystallography02:18

X-ray Crystallography

The size of the unit cell and the arrangement of atoms in a crystal may be determined from measurements of the diffraction of X-rays by the crystal, termed X-ray crystallography.
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Two-dimensional operation of a scanning optical microscope by vibrating knife-edge tomography.

Applied optics·2010
Same author

Wave-theory analysis of acousto-optic Bragg diffraction image formation.

Applied optics·2010
Same author

Improved space-marching algorithm for strong acousto-optic interaction of arbitrary fields.

Applied optics·2010
Same author

Visibility-dependent depth of focus for incoherent sinusoidal sources.

Applied optics·2010
Same author

Acoustooptic analysis of high frequency wideband sound field schlieren imaging.

Applied optics·2010
Same author

Three-dimensional ray theory of astigmatic Bragg diffraction image formation with anastigmatic illumination.

Applied optics·2010

Related Experiment Video

Updated: Jul 8, 2026

Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station
05:57

Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station

Published on: April 1, 2020

Comparison of phased-array Bragg cells operating in the second order

R J Pieper, A Korpel

    Applied Optics
    |September 1, 1984
    PubMed
    Summary

    No abstract available in PubMed .

    More Related Videos

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
    10:39

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

    Published on: October 11, 2016

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    Related Experiment Videos

    Last Updated: Jul 8, 2026

    Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station
    05:57

    Characterization of SiN Integrated Optical Phased Arrays on a Wafer-Scale Test Station

    Published on: April 1, 2020

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
    10:39

    Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

    Published on: October 11, 2016

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015