Combined solar aureole and solar beam extinction measurements. 1: Calibration considerations
Applied Optics
|October 15, 1984
Abstract
No abstract available in PubMed .
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Flame Photometry: Overview
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
Radiation Pressure: Problem Solving
The radiation pressure applied by an electromagnetic wave on a perfectly absorbing surface equals the energy density of the wave. The wave's momentum also gets transferred to the surface when an electromagnetic wave is entirely absorbed by it. The rate at which momentum is transmitted to an absorbing surface perpendicular to the propagation direction equals the force on the surface.
The average value of the rate of momentum transfer divided by the absorbing area represents the average force per...
The average value of the rate of momentum transfer divided by the absorbing area represents the average force per...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Overview
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...


