Related Experiment Video
Updated: Jul 8, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Experiment study on fracture fixation with low rigidity titanium alloy: plate fixation of tibia fracture model in
Nozomu Sumitomo1, K Noritake, T Hattori
1Department of Materials Science and Engineering, Meijo University, 1-501 Shiogamaguchi, Tempaku-ku, Nagoya 468-8502, Japan. n_sumitomo@hotmail.com
Abstract:
In order to investigate bone tissue reaction to the low rigidity titanium alloy of TNTZ in bone plate fixation, animal experiment with rabbit was performed with X-ray follow-up and histological observation. Experimental fractures were made in rabbit tibiae, and fixed by different bone plates of SUS316L, Ti-6Al-4V and TNTZ. Although there was no significant difference in fracture healing, bone atrophy was observed in cortical bone especially under the bone plate, which was different in time course among three materials. The bone atrophy under the bone plate was confirmed as porous or poor bone tissue in histological observation. In addition, the diameter of the tibia bone was increased in TNTZ as the result of bone remodeling with a new cortical bone. It is confirmed that the elastic modulus of the bone plate will naturally influence bone tissue reaction to the bone plate fixation according to the Wolff's law of functional restoration.