Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Estimating linear functionals of a PET image.

P J Bickel1, Y Ritov

  • 1Dept. of Stat., California Univ., Berkeley, CA.

IEEE Transactions on Medical Imaging
|January 1, 1995
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Atherosclerosis and arteriosclerosis parameters in stroke patients associate with paraoxonase polymorphism and esterase activities.

European journal of neurology·2013
Same author

[Splice sites are overrepresented in Pasilla binding motif clusters in D. melanogaster genes].

Biofizika·2012
Same author

Trial to trial variability in either stimulus or action causes apparent correlation and synchrony in neuronal activity.

Journal of neuroscience methods·2001
Same author

Failure in identification of overlapping spikes from multiple neuron activity causes artificial correlations.

Journal of neuroscience methods·2001
Same author

The neuronal refractory period causes a short-term peak in the autocorrelation function.

Journal of neuroscience methods·2001
Same author

Discussion of "The evaluation of forensic DNA evidence".

Proceedings of the National Academy of Sciences of the United States of America·1997
Same journal

MUST: Multi-style virtual staining with incomplete pairs.

IEEE transactions on medical imaging·2026
Same journal

BrainCL: Transformer-Based Brain Network Contrastive Learning with Multi-Order Topology and Salience Masking.

IEEE transactions on medical imaging·2026
Same journal

LLM-enhanced Neuron Segmentation and Reconstruction in Complex Mouse Brain Images.

IEEE transactions on medical imaging·2026
Same journal

Matrixed-Spectrum Decomposition Accelerated Linear Boltzmann Transport Equation Solver for Fast Scatter Correction in Multi-Spectral CT.

IEEE transactions on medical imaging·2026
Same journal

The Ritz Adjoint Method for MRI Pulse Design.

IEEE transactions on medical imaging·2026
Same journal

Physiology-guided Self-supervised Learning for Simultaneous Dual-Tracer PET Separation.

IEEE transactions on medical imaging·2026
See all related articles

Finite detectors in Positron Emission Tomography (PET) imaging introduce bias. This study proposes a bias correction method, improving PET image functional estimation accuracy with a finite detector system.

Area of Science:

  • Medical Imaging
  • Nuclear Medicine
  • Image Reconstruction

Background:

  • Positron Emission Tomography (PET) imaging relies on detectors to capture data.
  • The finite number of detectors in PET systems can introduce errors in image analysis.
  • Accurate estimation of image functionals is crucial for quantitative PET studies.

Purpose of the Study:

  • To analyze the impact of a finite detector count on PET image functional estimation.
  • To develop a novel estimator that corrects for detector-induced bias.
  • To improve the accuracy of quantitative measurements in PET imaging.

Main Methods:

  • Direct estimation of bounded linear functionals from detector counts.
  • Quantifying the bias introduced by detector binning to order D(-2).

Related Experiment Videos

  • Developing a data-driven bias correction for the proposed estimator.
  • Main Results:

    • The study quantifies the bias associated with a finite number of detectors (D).
    • An estimator was developed that directly uses detector counts.
    • The proposed bias correction significantly reduces estimation error to o(D(-2)).

    Conclusions:

    • Finite detector numbers in PET systems necessitate bias correction for accurate functional estimation.
    • Direct estimation from detector counts, coupled with bias correction, enhances quantitative PET analysis.
    • The developed estimator offers improved accuracy for PET image-based measurements.