Spill and leakage using a drug preparation system based on double-filter technology
Olle Nygren1, Eva Olofsson, Lennart Johansson
1Department of Chemistry, Umeå University, SE-901 87 Umeå, Sweden. olle.nygren@chem.umu.se
The Annals of Occupational Hygiene
|January 25, 2008
Summary
The Tevadaptor drug-handling system effectively minimizes cytotoxic drug spills during preparation, showing performance comparable to closed systems. This new system significantly reduces exposure risks for healthcare professionals handling hazardous medications.
Area of Science:
- Pharmaceutical Technology
- Occupational Health and Safety
- Drug Delivery Systems
Background:
- Occupational exposure to cytotoxic drugs is a significant concern in healthcare settings.
- Various drug-handling systems aim to minimize spills and leakage during preparation.
- Independent testing methods are crucial for evaluating the efficacy of these systems.
Purpose of the Study:
- To evaluate the spill and leakage performance of the Tevadaptor drug-handling system during cytotoxic drug preparation.
- To compare the Tevadaptor system's performance against established drug-handling systems and closed systems.
- To assess the safety and reliability of the Tevadaptor system in reducing occupational exposure.
Main Methods:
- A modified Technetium test method using Technetium-99m as a tracer substance was employed.
- The Tevadaptor system was tested across 75 drug preparations.
- Spill and leakage quantities were meticulously measured for each preparation.
Main Results:
- The Tevadaptor system demonstrated minimal spill, with all preparations showing less than 100 nl.
- Seventy out of 75 preparations exhibited spills of less than 1 nl.
- Performance was comparable to other tested systems like isolators and PhaSeal.
Conclusions:
- The Tevadaptor drug-handling system exhibits excellent performance in minimizing cytotoxic drug spills.
- Its efficacy is comparable to existing drug-handling systems considered closed systems.
- The Tevadaptor system offers a viable solution for reducing occupational exposure to hazardous drugs.
Related Concept Videos
Modified-Release Drug Delivery Systems: Rate-Programmed II
Rate-programmed drug delivery systems release drugs in a controlled manner to maintain therapeutic levels. Three main designs include reservoir, matrix, and hybrid systems.Reservoir systems consist of a drug core enclosed within a membrane that controls drug release. In non-swelling reservoir systems, polymers like ethyl cellulose or polymethacrylates are used. These do not hydrate in aqueous media and control release through membrane thickness, porosity, or insolubility. This type includes...
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Hemoperfusion and hemofiltration are critical techniques in medical treatments to eliminate accumulated drugs, metabolites, and electrolytes from the bloodstream. These methods are particularly vital in cases of accidental poisoning and drug overdose.Hemoperfusion involves passing blood through an adsorbent material to remove unwanted substances. The main adsorbents used in hemoperfusion include activated charcoal and Amberlite resins. Activated charcoal can adsorb both polar and nonpolar...
Filtration
Filtration is a physical separation process that involves passing a suspension through a porous medium to separate solids from fluids. During filtration, solids collect on the porous medium while liquids, also collectively known as the filtrate, pass through. The filtration medium is selected based on the filtration purpose, quantity, and nature of the precipitate. The general criteria for a suitable filtering medium are that it is inert, mechanically strong, nonabsorbent toward dissolved...