Related Experiment Video
Updated: Jul 7, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
BTEX determination in water matrices using HF-LPME with gas chromatography-flame ionization detector
A Sarafraz-Yazdi1, A H Amiri, Z Es'haghi
1Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Iran. asyazdi@ferdowsi.um.ac.ir
Abstract:
In the present work, a sample pre-treatment technique for the determination of trace concentrations of benzene, toluene, ethyl benzene and xylene (BTEX) in aqueous samples has been developed and applied to analysis of the selected analytes in environmental water samples. The extraction procedure is based on coupling polypropylene hollow-fiber liquid phase microextraction (HF-LPME) with gas chromatography by flame ionization detection (GC-FID). The effective parameters such as organic solvent, extraction time, agitation speed and salting effect were investigated. Good reproducibilities of the extraction performance were obtained, with the RSD values ranging from 2.02 to 4.61% (n=5). The method provided 41.47-128.01 fold preconcentration of the target analytes. The limits of detections for the BTEX were in the range of 0.005-03microg ml(-1). In addition, sample clean-up was achieved during LPME due to the selectivity of the hollow fiber, which prevented undesirable large molecules from being extracted. Real samples (River and waste waters) containing BTEX were examined using this method with good linearity and precision (RSDs most lower than 6.00%, n=5). All experiments were carried out at room temperature, 22+/-0.5 degrees C.
More Related Videos
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
08:17Chemical Analysis of Water-accommodated Fractions of Crude Oil Spills Using TIMS-FT-ICR MS
Published on: March 3, 2017
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Flame Photometry: Lab
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Lab
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...