Related Experiment Video
Updated: Jul 7, 2026

Non-invasive Parenchymal, Vascular and Metabolic High-frequency Ultrasound and Photoacoustic Rat Deep Brain Imaging
Published on: March 2, 2015
Contemporary ultrasound systems allow high-resolution transcranial imaging of small echogenic deep intracranial
Uwe Walter1, Martin Kanowski2, Jörn Kaufmann2
1Department of Neurology, University of Rostock, Gehlsheimer Str. 20, D-18147 Rostock, Germany.
Abstract:
Transcranial sonography (TCS) of small deep brain structures, such as substantia nigra and brainstem raphe, is increasingly used for assessment of neurodegenerative disorders. Still, there are reservations against TCS because of the smallness of evaluated structures and constraints on image resolution that is discussed to be lower compared to magnetic resonance imaging (MRI). To evaluate two different-generation TCS systems in visualizing fine intracranial structures, we studied image resolution on a phantom consisting of 0.80 mm x 1.05 mm regular meshwork of nylon threads embedded in a wet, gel-filled ex vivo human skull. Imaging was performed with a former-generation and a present-day clinical ultrasound system and for comparison with MRI. In axial direction of insonation both TCS systems resolved 0.80-mm and 1.05-mm thread-to-thread distance at depths between 55 and 120 mm using transmission frequencies > or =2.5 MHz. The meshwork, however, was recognizable as such only with the contemporary TCS system at depths between 60 and 85 mm due to its higher lateral resolution. MRI resolved the meshwork if image resolution was chosen sufficiently high but not if realistic clinical conditions were applied with its trade-offs between image SNR, resolution, total scan time, and unavoidable head motion during the latter. Hence, if the requirements for optimal TCS image resolution are fulfilled, i.e. sufficient acoustic bone window, increased echogenicity of target structure and its localization in a distance of maximum +/-15 mm from midsagittal plane, findings suggest that contemporary TCS systems achieve higher image resolution of intracranial structures in comparison not only to former-generation systems, but also to MRI under clinical conditions.
More Related Videos
06:29Real-Time Intravital Multiphoton Microscopy to Visualize Focused Ultrasound and Microbubble Treatments to Increase Blood-Brain Barrier Permeability
Published on: February 5, 2022
05:32A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging
Published on: June 21, 2017
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...